Auto Maintenance

Share us

ne Generator Rotor Maintenance

origin: China
packaging: In cases
MOQ: 1

Description

China 10MW Steam Turbine Generator Rotor Maintenance with High-Quality, Leading 10MW Steam Turbine Generator Rotor Maintenance Manufacturers & Suppliers, find 10MW Steam Turbine Generator Rotor Maintenance Factory & Exporters.

10MW Steam Turbine Generator Rotor Maintenance QNP Maintenance and Installation Engineering Co., Ltd. is QNP`s subsidiary company, and has power engineering construction qualification. Generator rotor ground Symptom: Generator grounding one point or two points grounding light plate light. Fault Analysis: Generator rotor winding insulation damage, coil deformity and severe dust and greasy attached in the ends seriously are all leading to the grounding of the generator rotor windings. When the generator rotor winding grounding in one point, there is electrical current pass as the ground does not constitute an electrical circuit. However, after one point grounded, it is easy of leading another grounding point. If any part in excitation circuit ground, it can form ground fault of two or more points ground. It is very dangerous. After the failure, the rotor windings are short-circuited. Because of the small winding DC resistance, the excitation current will increase. So the magnetic field of generator is out of balance, and main magnetic flux reduces largely. So the STG will vibrant strongly. Meanwhile the power factor of the generator will be increased significantly and get into leading phase running (absorption of reactive power from the grid). The stator field becomes in the frond and the rotor field becomes in the back. It will make the stator current increases. If the watcher notice that there is no excitation varying but the excitation current and stator current suddenly increases, and the excitation voltage and AC voltage are all suddenly drop, and power factor meter indicates increasing or leading phase, it means the generator rotor grounded or inter-turn short circuited. You should shut down the STG and blow-out magnetic. Please inspect the excitation system and rotor windings, and find out the short circuit point and treat it. 135MW Steam Turbine Rotor slignment 50MW Steam Turbine Rotor Maintenance http://www.qnpturbines.com

10MW Steam Turbine Generator Rotor, Steam Turbine Generator Rotor Maintenance, Steam Turbine Generator Rotor,

Read More

Previous

on back pressure steam turbine...

Next

cy back pressure steam turbine...

Shandong Qingneng Power Co., Ltd.

America,Japan,England,Australia

Read More

Contact

Tel: 15624145254
Address:
No.3011 Haidai North Road,Qingzhou City, Shandong Province, China, Shandong, China,

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多